Advantages of Dual-Energy Scalpel:

Dual-Energy Needle - Tungsten Needle Electrode
Features:
- Extremely Sharp Tip (≤5um): Fast and precise cutting with minimal blood loss, low-temperature cutting and coagulation significantly reduce thermal damage to tissues during surgery and protect nerves, greatly shortening surgery and recovery time.
- 4mm Needle Tip Length: Effectively prevents accidental tissue damage while ensuring deep needle penetration without unnecessary tissue injury.
- Retractable Shaft: The tungsten needle electrode comes in fixed and retractable shaft types. The retractable shaft electrode allows for adjustable electrode length during clinical surgery, with a retractable length range of 35-180mm, enabling both shallow and deep surgeries to be performed with a single electrode, enhancing clinical flexibility and cost-effectiveness.
- Retractable Blade: The scraping and suction tungsten needle electrode features a retractable blade. When not energized, the scraping blade can be used for scraping, raking, pushing, and pulling operations. It also has suction capabilities to simultaneously remove smoke and blood during surgery, maintaining a clear field of vision, improving surgical quality, and protecting healthcare workers' health.
- Suction Device: Equipped with a built-in suction device to promptly remove smoke during surgery, improving surgical quality and protecting the health of healthcare workers.
Applicable Range:
Suitable for fine tissue dissection and coagulation during surgery, especially for breast and thyroid surgery, ENT, oral and maxillofacial, plastic and cosmetic surgery, neurosurgery, and minimally invasive orthopedic procedures.

Dual-Energy Curved Needle
Features:
- Fast and Precise Cutting: Offers fast cutting speed, precise cutting, minimal thermal tissue damage, and low blood loss during surgery. The curved design allows for tissue cutting in specific areas and can be freely bent, such as for treatments at the base of the tongue.
- Compatibility: Can be connected to all high-frequency energy output platforms.
Applicable Range:
Widely used in various surgical procedures. Particularly suitable for thyroid surgery, breast surgery, ENT surgery, neurosurgery, and oral surgery.

Dual-Energy Blade - Blade Electrode
Features:
- Coated Blade: The blade is covered with a high-tech non-stick coating, facilitating the handling of eschar during surgery and preventing secondary bleeding.
- Retractable Shaft: The blade electrode comes in fixed and retractable shaft types. The retractable shaft type features adjustable length, normally 35mm, extending up to 180mm, allowing for any length between 35-180mm. This eliminates the need for the surgeon to change blades of different lengths, reducing surgery time and workload.
- Retractable Blade: The scraping and suction blade electrode has a retractable blade, enabling simultaneous scraping and suction, which is particularly useful for lymph node dissection. It also removes smoke and blood during surgery, maintaining a clear field of vision.
- 360-Degree Rotation: The electrode is designed for 360-degree rotation, providing ease of operation for the surgeon.
- Compatibility: Can be connected to all high-frequency energy output platforms.
Applicable Range:
Suitable for tissue cutting, coagulation, and scraping operations during surgical procedures.

Dual-Energy Hook Electrode
Features:
- Coated Blade: The blade is covered with a high-tech non-stick coating, facilitating the handling of eschar during surgery and preventing secondary bleeding.
- Retractable Shaft: Available in fixed and retractable shaft types. The retractable shaft extends from 200mm to 330mm, allowing for flexible adjustment without the need to change blades of different lengths.
- Retractable Blade: The blade can be freely extended and retracted, with suction capability to remove blood, keeping the surgical field clear and enhancing surgical quality.
- Controlled Operation: Designed to meet the habitual use of surgeons.
- Suction Device: Equipped with a built-in suction device to promptly remove smoke during surgery, improving surgical quality and protecting the health of healthcare workers.
Applicable Range:
Suitable for fine tissue dissection and coagulation during surgery, especially for thyroid, breast, ENT, oral and maxillofacial, plastic and cosmetic surgery, neurosurgery, and minimally invasive orthopedic procedures.

Dual-Energy Scissors
Features:
- Design: The dual-energy scissors are designed according to the surgical habits and grip styles of Chinese surgeons, incorporating fluid dynamics principles. Innovatively developed with a hand-operated control button, the scissors are well-crafted, comfortable to hold, easy to use, and reduce fatigue during prolonged operations. Lightweight, flexible, and durable, they provide a superior user experience, reducing the surgeon's burden during surgery.
- Scissor Head Design: The scissor head features a unique design with a length of 5-8mm and a tip width of 1mm. The slender structure allows for low-temperature cutting and coagulation, minimizing thermal damage, making it suitable for precise tissue cutting and effectively protecting nerves and important tissues.
- Material: The scissor head is made from a specially formulated material with excellent anti-adhesion properties.
- Compatibility: Can be connected to all high-frequency generators with bipolar output.
Applicable Range:
Suitable for precise tissue cutting, coagulation, and dissection in open surgeries, particularly in thyroid surgery and other similar procedures.

Dual-Energy Forceps
Features:
- Safety: The forceps tips are made with special materials and processes, ensuring no adhesion, no carbonization, and low-temperature cutting and coagulation, effectively protecting nerves and vital organs.
- Effectiveness: Excellent hemostatic effect for small vessels (diameter <4mm).
- Practicality: Easier access to surgical sites, allowing simultaneous cutting and coagulation without needing to change instruments, reducing surgery time and simplifying the operation.
- Comfort: Moderate elasticity and excellent hand feel, reducing fatigue during prolonged use.
- Compatibility: Can be connected to all high-frequency generators with bipolar output.
Applicable Range:
Suitable for low-temperature, precise tissue cutting and coagulation in various surgeries. Particularly applicable for thyroid, ENT, orthopedic, neurosurgery, and head and neck surgeries.

Dual-Energy Clamp
Features:
- Design: Ingeniously designed for comfort and ease of use, reducing fatigue during prolonged operations. Lightweight, flexible, and durable, offering a superior user experience for surgeons.
- Clamp Head Design: The clamp head is delicately designed with a slender structure for low-temperature cutting and coagulation, minimizing thermal damage, suitable for precise tissue dissection, and effectively protecting nerves and important tissues.
- Clamp Head Craftsmanship: Manufactured with special processes to prevent adhesion and carbonization, enabling low-temperature cutting and dissection.
- Detachable Blades: The second-generation dual-energy clamp allows for the sheath and rod to be disassembled for individual sterilization, thoroughly removing residual tissue to meet sterilization standards, prevent cross-infection, and improve the utilization rate of consumables.
- Function Tube Lengths: The second-generation dual-energy clamp has functional tube lengths of 140mm, 230mm, and 360mm, suitable for precise cutting and dissection in both open and laparoscopic surgeries.
- Compatibility: Can be connected to all high-frequency generators with bipolar output.
Applicable Range:
Suitable for precise dissection, cutting, coagulation, and nerve protection in open and laparoscopic surgeries. Particularly applicable for thyroid and head and neck surgeries.

TaiShi Nail
Features:
- Chin Foramen Spacing: The spacing between the chin foramina is 5-6cm, ensuring that the single incision hardly affects the mental nerve.
- No Skin Flap Collapse: Continuous suction holes can remove smoke and water vapor, maintaining a clear surgical field.
- Sufficient Surgical Space: Fully meets the needs of the surgical space, allowing three instruments to operate simultaneously within the surgical cavity. Central area lymph node dissection is more thorough.
- Nerve and Parathyroid Protection: Provides excellent exposure and protection for the recurrent laryngeal nerve and parathyroid glands.
- Shorter Pathway: The relatively short pathway allows for the treatment of bilateral lesions.
- No CO2 Gas Complications: Completely avoids complications related to CO2 gas, such as gas embolism, and potentially reduces the risk of tumor cell seeding caused by insufflation.
- Scar-Free Surface: Offers excellent cosmetic and privacy protection due to the lack of visible scars.
Applicable Range:
Suitable for endoscopic thyroid surgery (ETS) through transoral and transoral vestibular approaches. Applicable for thyroid surgery.